CPU RECOGNISE COIN ACCEPTOR

Model:C-315 (Multi-Coins Mode, must be with LED display)

OPERATION MANUAL OF CPU RECOGNISE COIN ACCEPTOR

(1)INTRODUCTION OF MAIN FUNCTION

  • Using the intelligent multi-function CPU system, automatically identify the coin by material , thickness and
    diameter .
  • Can set up 3 different value groups at the same time, every value set can program 15 coins .
  • Can at any time adjust to throw the accurate degree of the currency machine ,in keeping with different
    amenity demand .
  • The product include software guard system, this guard system has alarm system ,which prevent
    opportunistic behaviors .
  • Can connect the counter.
  • It can supply digital byte output and make some modification in the output program according the demand .

(2) SETTING INSTRUCTION OF PRODUCT:

  • Turn the sensitive switch to stir to the "NOM" position ("MGN" position) , then turn the setting
    switch to stir to the "SET" position. LED display "00"(display "P2").
  • Adjust the coin value in turn and let the LED display the value which you needed.
  • Deposit the coins in turn, the more you can programming are 15 coins .If less than 15 coins ,can
    add and store later .
  • If need to set up the other value group's coin after set up, then re-programming step 2 and step
  • If need exit, set up the setting switch to the "START" position, then can use it .
  • When need to cancel all of the programmed coins ,after finish step 1, LED display "00" then keep press the coin adjust switch ,you will be hear a "BI" sound and LED will display "C" ,this moment is ok .
  • If need to cancel one of the different value groups, finish step 1 and step 2, keep press the coin
    adjust switch, you will be hear a "BI" sound and LED will display "C", this moment is ok .


(3) STANDARDS AND OPERATIONG INSTRUCTION :

  • Apply to coin's diameter = 18m/m ¨C29m/m
  • Apply to coin's thickness = 1.2m/m ¨C 3.0m/m
  • Work voltage = DC12V
  • Temperature =-20 ~50


1. Operate with the game machine's standard. Switch to the correct mode with Normal Open(N.O) and
Normal Close (N.C.) Usually use Normal Open .

2. Switch to the correct speed (pulse) of coin machine.
FAST :25ms(short pulse signal)
MEDIUM:45ms(medium pulse signal)
SLOW:65ms(long pulse signal by TIMER SWITCH for synchronizing with your machine)

3. When the coin acceptor is used , the coin setting switch needs to be set correctly according to the coin
that was selected .

4. The switch which for adjusting the coin's value , can adjust the coin value when the coin
programming . "00-99" means how many times of the output pulse signal will be sent when the
programmed coin was deposited. "P2-P9" means a output pulse signal needs how many programmed
coins to be deposited.

5. The switch for test the coin's sensitive degree, it detects the difference between real/fake coin ,when
inserted .

6. Please turn on power about 10 minutes before using or setting
you can get the optimal effect

7. Connecting instructions of connector:
Gray line
Red line DC+12V
White line COIN Signal counter
Black line GND(Ground)
Gray line

Back