CPU RECOGNISE COIN ACCEPTOR
| Model: |
C-501 (Time Control Mode + Power Supply Box) |
-
Be able to adjust signal outputting length to match
the control for power supply time.
-
Be able to set by itself how much it accumulates for
outputting one signal.
-
Be able to receive multi-value coins when cooperate
with our multi-value coin acceptor.
-
The product ( time unit & power voltage) can do
the modification according to the customer's need.
COIN ACCEPTOR MANUAL(Accumulative & Time-control Mode )
PRODUCT SETTING INSTRUCTION:
1. Set signal output parameter (i.e. how much for outputting one signal):(Turn
FAST/MID/SLOW switch to “MID” position)
1) Turn the SENSITIVE SWITCH to stir to the “MGN” position,
and then turn SETTING SWITCH to stir to the “SET” position.
LED displays “1”. Adjust the value in turn and let the LED
display the value that you need (1~A0; A0=100). After finished turn
the SETTING SWITCH to stir to the “START” position, and
the SENSITIVE SWITCH to “NOM”, here you can go to the next
step for coin parameter setting. If user doesn’t set, it defaults
to “1”.
2) If need re-set, do same as above. Turn the SENSITIVE SWITCH to stir
to the “MGN” position, then turn the SETTING SWITCH to stir
to the “SET” position. Here LED display the value set before.
If you need set bigger value than before, just directly press the COIN
VALUE ADJUSTION SWITCH to add up; If you need set smaller value, keep
pressing the COIN VALUE ADJUSTION SWITCH until heard a “BI”
tone after 2 seconds, and LCD displays “1”, then press COIN
VALUE ADJUSTION SWITCH to make LED display the value you need.
E.g..: Set the signal output parameter as “10”. Coin parameter
($0.1 set as “01”; $0.5 set as “05”; $1.0 set
as “10”)
When insert a coin of $1.0, coin acceptor output one signal
When insert two coins of $0.5, coin acceptor output one signal
When insert coins of $0.5+$0.1+$0.1+$0.1+$0.1+$0.1, coin acceptor output
one signal
When inset coins of $0.1+$0.1+$0.1+$0.1+$0.1+$0.1+$0.1+$0.1+$0.1+$0.1,
coin acceptor output one signal.
(if only the amount of coins’ value is equal to “10”,
coin acceptor will output one signal)
2. Set coin parameter:( Turn FAST/MID/SLOW switch to “MID”
position)
1) Turn the SENSITIVE SWITCH to stir to the “NOM” position,
then turn the SETTING SWITCH to stir to the “SET” position.
LED displays “00”.
2) Adjust the coin value in turn and let the LED display the value (01~A0;A0=100)
which you need.
3) Deposit the coins in turn, the more you can program are 15 coins
.If less than 15 coins, can add and store in future.
4) If need to set up coins with other value after finished, then repeat
step 2 and step 3.If need exit, set up the SETTING SWITCH to the “START”
position, then it can use.
5) When need to cancel all of the programmed coins ,after finish step
1, LED display “00” ,then keep pressing the COIN VALUE ADJUSTION
SWITCH, you will hear a “BI” tone after 2 seconds and LED
will display “C” ,then it is ok .
6) If need to cancel coins in one same value, after executed step 1
and step 2, keep pressing the COIN VALUE ADJUSTION SWITCH, you will
be hear a “BI” sound and LED will display “C”,
here it is ok.
3.Set signal output length:(Turn the SENSITIVE SWITCH to the “NOM”
position)
1) Pulse signal output mode with normal value of 25ms, 45ms, and 65ms.
Turn FAST/MID/SLOW witch to “FAST” position, then turn SET
SWITCH to “SET” position, LED displays 25, it means the
width of current pulse signal is 25ms, press COIN VALUE ADJUST SWITCH
to adjust, there are there available unit of 25, 45, 65. After selection
turn SET SWITCH to “START” position, then turn FAST/MID/SLOW
switch to “MID” position.
2) If need it be longer, coin acceptor offers a pulse output mode that
take minute as unit, this setting is priority value. Once this mode
is set it will replace the normal value, the operation is as below:
a) Turn FAST/MID/SLOW switch to “SLOW” position, then turn
SET SWITCH to “SET” position, LED displays 00, (00~99) are
available, when value displayed is 15, it means width of one pulse signal
is 15 (seconds) minutes, and coin acceptor doesn’t accept coins
when send out signals again.)
b) This value is programmable via directly pressing COIN VALUE ADJUST
SWITCH, after finishing adjustment turn SET SWITCH to “START”
position, then turn FAST/MID/SLOW witch to “MID” position.
STANDARDS AND OPERATIONG INSTRUCTION:
Apply to coin’s diameter = 18mm ~ 29mm Apply to coin’s thickness
= 1.2mm ~ 3.0mm
Work voltage = DC12V ± 20% Temperature =-20?~50?
1. When the coin acceptor is used, the COIN SETTING SWITCH needs to
be set correctly according to the coin that was selected.
2.COIN VALUE ADJUSTION SWITCH: to adjust the value need in setting signal
output unit and coin value parameter.
3. SENSITIVE SWITCH: to test the coin’s sensitive degree, it detects
the difference between real/fake coins, when inserted.
Connecting instructions of connector:
Red line ——DC+12V(V+)
White line——COIN Signal(COIN)
Black line ——GND(Ground)
Gray line——Counter(COUNT),(when don’t connect to counter,
this line can unused)
|